| Software controlled Data acquisition Clamping Built in test functions System test Transducer test Sample Interval /48, 1/32, 1/16, 1/8, ..., 8 ms Number of Samples per Trace Max. 3000 K-samples System Input Noise < 0.12 ?V RMS @ 1 ms (1.3 nV/Sqrt(Hz) at 7.2 kHz bandwidth) Instantaneous Dynamic Range > 120 dB @ 1 ms Total Harmonic Distortion < 130 dB (22 * 10-6 %) Common Mode Rejection Ratio > 90 dB Gain Accuracy between Channels > 1 % Integral Nonlinearity > 96 dB Cross-talk < 107 dB | Analogue Anti-Alias Filter 7,2 kHz 6 dB / Octave Analogue Low-Cut Filter S1 Hz 6 dB / Octave Digital Anti-Alias Filter 19.2 kHz @ 1/48 ms 6.4 kHz @ 1/16 ms 1.5 kHz @ ¼ ms 100 Hz @ 4 ms | | 12.8 kHz @ 1/32 ms 3.2 kHz @ 1/8 ms 800 Hz @ 1/2 ms 200 Hz @ 2 ms 50 Hz @ 8 ms | Rejection at Nyquist Frequencies -130 dB Operation Temperature Range -40°C to +105°C Dimensions of one receiver unit 780 mm length, 55 mm diameter Power 24 Vdc Current (electronics) 0.1 A Motor clamping current 0.4 A Max current (motor clamping limit) 2A / 0.5s Maximum Depth 3000 m A/D Converter 24 bit delta sigma technology Frequency Range Version LF 3 Hz - 500 Hz Version SF 16 Hz - 2000 Hz Version HF 40 Hz - 6000 Hz |